Operating Your Appliance 17
© Travis Industries 100-01260 4121205
Adjusting the Burn Rate
Use the air control slider to control the burn rate of the stove. See the illustration below for details.
Approximate Air Control Settings
Overnight Burn
Fully out to 7.1mm open
Medium Burn 7.1mm to 7.9mm open
Medium High Burn 7.9mm to 11.1mm open
High Burn 11.1mm to full in
The air control becomes hot during operation - use gloves or a tool to prevent burns.
The air control may take several minutes to influence the burn rate. When making adjustments, you
may wish to let the stove burn for 10 minutes to gauge performance.
Ash Removal
Ashes should be placed in a metal container with a tight fitting lid. Other waste is not placed in
this container. The closed container of ashes should be placed on a non-combustible floor or on
the ground, away from all combustible materials, pending final disposal. If the ashes are
disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed
container until all cinders have thoroughly cooled.