Avalon Winthrop TRV Installation Manual

Browse online or download Installation Manual for Fireplaces Avalon Winthrop TRV. Avalon Winthrop TRV Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
864TRV
Fireplace
Tested and Listed by
OMNI-Test Laboratories, Inc.
Beaverton, Oregon
Report # 028-F-59-5
ANSI Z21.88b-2003
Built-In Direct Vent Fireplace
Natural Gas or Propane
Residential or Mobile Home
WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the
gas supplier.
This appliance may be installed as an OEM installation in a manufactured (mobile) home and must be
installed in accordance with the manufacturer’s instructions and the manufactured home construction
and safety standard, Title 24 CFR, Part 3280.
This appliance is only for use with the type(s) of gas indicated on the rating plate. A conversion kit is
supplied with the appliance.
Installation Manual
Installer: After installation give this manual to the home-
owner and explain operation of this heater.
Copyright 2007, T.I. $10.00 100-01173_001 4050714
4800 Harbour Pointe Blvd. SW
Mukilteo, WA 98275
Page view 0
1 2 3 4 5 6 ... 67 68

Summary of Contents

Page 1 - Fireplace

864TRVFireplaceTested and Listed byOMNI-Test Laboratories, Inc.Beaverton, OregonReport # 028-F-59-5ANSI Z21.88b-2003• Built-In Direct Vent Firepl

Page 2 - CAUTION:

10 Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Fireplace Placement Requirements• The fireplace requires a

Page 3 - Table of Contents 3

Installation (for qualified installers only) 11© Travis Industries 4050714 100-01173_001Minimum Framing Dimensions - Rear Vent ConfigurationRoute the

Page 4 - 4 Safety Precautions

12 Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Minimum Framing Dimensions - Top Vent ConfigurationRoute the el

Page 5 - Safety Precautions 5

Installation (for qualified installers only) 13© Travis Industries 4050714 100-01173_001Nailing BracketsNOTE: Additional nailing brackets are provide

Page 6 - 6 Features and Specifications

14 Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Corner Installations - Rear Vent ConfigurationA typical 45° i

Page 7 - Installation Overview

Installation (for qualified installers only) 15© Travis Industries 4050714 100-01173_001Corner Installations - Top Vent ConfigurationA typical 45°

Page 8 - Back of Fireplace

16 Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Gas Line RequirementsMASSACHUSETTS INSTALLATIONS - WARNING:TH

Page 9

Installation (for qualified installers only) 17© Travis Industries 4050714 100-01173_001Gas Line LocationThe gas inlet is located 3" above the b

Page 10 - Raised Fireplaces

18 Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Electrical Connection (required)• The electrical line to t

Page 11

Installation (for qualified installers only) 19© Travis Industries 4050714 100-01173_001Wall Switch or Thermostat InstallationWiring Diagram (Millivo

Page 12

2 Introduction© Travis Industries 4050714 100-01173_001OverviewThis manual details the installationrequirements for the 864TRV fireplace. Forop

Page 13 - 5/8” Drywall

20 Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Vent Requirements• The gas appliance and vent system must

Page 14

Installation (for qualified installers only) 21© Travis Industries 4050714 100-01173_001Approved Vent• Rear vent configurations use 8" diame

Page 15 - Minimum 1/2" Clearance

22 Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Approved Vent ConfigurationsRestrictor Position• Intake and ex

Page 16 - Gas Line Requirements

Installation (for qualified installers only) 23© Travis Industries 4050714 100-01173_001Intake Restrictor AdjustmentRemove these screws.Loosen these

Page 17 - Left Side Gas Inlet

24 Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Diffuser Plate AdjustmentCertain vent configurations require

Page 18

Installation (for qualified installers only) 25© Travis Industries 4050714 100-01173_001Rear Vent Configuration with Horizontal Termination (no verti

Page 19

26 Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Rear Vent Configuration with Horizontal Termination (with verti

Page 20 - Vent Requirements

Installation (for qualified installers only) 27© Travis Industries 4050714 100-01173_001Rear Vent Configuration with Vertical Termination• The term

Page 21 - Vent Installation

28 Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Top Vent Configuration with Horizontal Termination• The termi

Page 22 - Approved Vent Configurations

Installation (for qualified installers only) 29© Travis Industries 4050714 100-01173_001Top Vent Configuration with Vertical Termination• The termi

Page 23 - Intake Restrictor Adjustment

Table of Contents 3© Travis Industries 4050714 100-01173_001IntroductionOverview...2List

Page 24 - Diffuser Plate Adjustment

30 Installation (for qualified installers only)Travis Industries 4050714 100-01173_001 Termination RequirementsNOTE: Measure all clearances from the

Page 25 - 2' (max)

Installation (for qualified installers only) 31© Travis Industries 4050714 100-01173_001Hearth RequirementsDo not build a hearth more than 1” above t

Page 26

32 Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Facing Requirements• This appliance is designed to allow

Page 27 - Diffuser Position # 2

Installation (for qualified installers only) 33© Travis Industries 4050714 100-01173_001Facing OverviewUpgrade faces are available for this fireplace

Page 28

34 Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Thin Facing Installation (tile, marble, or other non-combustibl

Page 29

Installation (for qualified installers only) 35© Travis Industries 4050714 100-01173_001Thin Facing Installation (tile, marble, under 1" thick)

Page 30 - Termination Requirements

36 Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Thick Facing Installation (stone, brick, or other non-combustib

Page 31 - Hearth Requirements

Installation (for qualified installers only) 37© Travis Industries 4050714 100-01173_001 Thick Facing with Fireplace Xtrordinair (FPX) Arched FacesTh

Page 32 - Facing Requirements

38 Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Thick Facing Installation - Side ViewSIDE OF FIREPLACEDrywallMa

Page 33 - Facing Overview

Installation (for qualified installers only) 39© Travis Industries 4050714 100-01173_001Mantel Requirements• Use the table below to determine

Page 34 - Tile Line

4 Safety PrecautionsTravis Industries 4050714 100-01173_001Safety Warnings:• Failure to follow all of the requirements may result in property damage,

Page 35 - (with no Hearth)

40 Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Installation Example - Build-Out (Dog-House) with Horizontal Te

Page 36 - Faces" on page 37

Installation (for qualified installers only) 41© Travis Industries 4050714 100-01173_001Installation Example - Build-In with Horizontal Termination•

Page 37 - Hearth Line

42 Finalizing the Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Steps for Finalizing the Installation1. Remove

Page 38 - SIDE OF FIREPLACE

Finalizing the Installation (for qualified installers only) 43© Travis Industries 4050714 100-01173_0018. Check the air shutter following the di

Page 39

44 Finalizing the Installation (for qualified installers only)Travis Industries 4050714 100-01173_0019. Turn the flame adjust knob to its highes

Page 40 - Top View

Finalizing the Installation (for qualified installers only) 45© Travis Industries 4050714 100-01173_001Glass Frame Removal and InstallationWarning: T

Page 41

46 Finalizing the Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Glass Frame Removal and Installation (continued)

Page 42 - Pilot Flame Inspection

Finalizing the Installation (for qualified installers only) 47© Travis Industries 4050714 100-01173_001Log Set InstallationRear Log InstallationPlace

Page 43 - Air Shutter Adjustment

48 Finalizing the Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Right Log InstallationPlace the right log as s

Page 44

Finalizing the Installation (for qualified installers only) 49© Travis Industries 4050714 100-01173_001Left Log InstallationPlace the left log as

Page 45

Safety Precautions 5© Travis Industries 4050714 100-01173_001Safety Warnings (continued):• Allow the heater to cool before carrying out any maintenan

Page 46

50 Finalizing the Installation (for qualified installers only)Travis Industries 4050714 100-01173_001 Center Log InstallationNote how the center log

Page 47 - Log Set Installation

Finalizing the Installation (for qualified installers only) 51© Travis Industries 4050714 100-01173_001Ember InstallationPlace the embers along the h

Page 48 - Right Log Installation

52 Finalizing the Installation (for qualified installers only)Travis Industries 4050714 100-01173_001LP Conversion InstructionsInstall the conversion

Page 49 - Left Log Installation

Finalizing the Installation (for qualified installers only) 53© Travis Industries 4050714 100-01173_0013 Follow the directions below to replace

Page 50 - Center Log Installation

54 Finalizing the Installation (for qualified installers only)Travis Industries 4050714 100-01173_0015 Replace the rear burner. Set the rear burner

Page 51 - Ember Installation

Finalizing the Installation (for qualified installers only) 55© Travis Industries 4050714 100-01173_0018 Make the gas line connection, bleed the

Page 52 - LP Conversion Instructions

56 Optional Equipment (for qualified installers only)Travis Industries 4050714 100-01173_001Fireback InstallationWARNING Turn off gas to the applianc

Page 53 - NG (Natural Gas) Orifice

Optional Equipment (for qualified installers only) 57© Travis Industries 4050714 100-01173_001Blower (part # 99000156)Make sure power to the fireplac

Page 54

58 Optional Equipment (for qualified installers only)Travis Industries 4050714 100-01173_0013. Attach the blowers (use the #8 x 3/4" silver scr

Page 55

Optional Equipment (for qualified installers only) 59© Travis Industries 4050714 100-01173_0014. Attach the wiring and rheostat assembly follow

Page 56 - Fireback Installation

6 Features and SpecificationsTravis Industries 4050714 100-01173_001Installation Options• Residential or Mobile Home• Straight or Corner Plac

Page 57 - Blower (part # 99000156)

60 Optional Equipment (for qualified installers only)Travis Industries 4050714 100-01173_001Grill InstallationCertain faces allow for installation

Page 58

Optional Equipment (for qualified installers only) 61© Travis Industries 4050714 100-01173_001Remote Control Receiver Installation (2 Options)The in

Page 59 - SOLENOID-BLU

62 Optional Equipment (for qualified installers only)Travis Industries 4050714 100-01173_001Extra Room Power Heat DuctInstallation OverviewThe optio

Page 60 - Grill Installation

Optional Equipment (for qualified installers only) 63© Travis Industries 4050714 100-01173_001Duct Installation InstructionsDetermine the route for

Page 61

64 Optional Equipment (for qualified installers only)Travis Industries 4050714 100-01173_001Floor MountingCut a hole between floor joists for the blo

Page 62 - Extra Room Power Heat Duct

Optional Equipment (for qualified installers only) 65© Travis Industries 4050714 100-01173_001Install the air duct. Each section, when joined,

Page 63 - Wall or Ceiling Mounting

66 Optional Equipment (for qualified installers only)Travis Industries 4050714 100-01173_001Wiring InstructionsWarning: All wiring should be done

Page 64 - Floor Mounting

Optional Equipment (for qualified installers only) 67© Travis Industries 4050714 100-01173_0012 Follow the directions below to wire the rheostat. NO

Page 65

68 IndexTravis Industries 4050714 100-01173_001IndexAdditional Items Required...7Air Shutter Adjustment ...

Page 66 - Wiring Diagram -864TRV

Installation (for qualified installers only) 7© Travis Industries 4050714 100-01173_001Packing List• Propane Conversion Kit• Log Set• Wall Switch

Page 67 - MAINTENANCE INSTRUCTIONS

8 Installation (for qualified installers only)Travis Industries 4050714 100-01173_001Top Vent or Rear Vent ConfigurationThis appliance is shipped

Page 68 - 68 Index

Installation (for qualified installers only) 9© Travis Industries 4050714 100-01173_001Converting theFireplace to Top Vent(continued)Remove the 12 sc

Comments to this Manuals